What Size Air Conditioner Do I Need for a 250 Sq Ft Room?

250 sq ft closes the 6,000 BTU/hr row and opens the 7,000 BTU/hr row.

Full breakdown: BTU per square foot.

Quick answer: At 250 sq ft you are on the line between 6,000 BTU/hr (150 up to 250 sq ft) and 7,000 BTU/hr (250 up to 300 sq ft). Heavy shade is the case for 6,000. Sun or extra regular occupants are the case for 7,000. Apply the 10% adjustment only after that choice.
Affiliate

Affiliate disclosure: as an Amazon Associate, we earn from qualifying purchases — at no cost to you.

ENERGY STAR 6,000 BTU window air conditioners on Amazon

Capacity from the chart

Area to be cooledCapacity neededSource
150 up to 250 sq ft6,000 BTU/hrENERGY STAR
250 up to 300 sq ft7,000 BTU/hrENERGY STAR

The gap between these two capacities is 1,000 BTU/hr. That is 7,000 minus 6,000, and it is bigger than either 10% swing. Ten percent of 6,000 is 600 BTU/hr. Ten percent of 7,000 is 700 BTU/hr. If you only argue about shade and ignore which row 250 sq ft belongs on, you are tuning the smaller number.

How to size it

Read 250 sq ft as the end of one published range and the start of the next. ENERGY STAR writes both as "up to," so the chart itself does not award the square foot to a single row. Use the room, not an average: shaded rooms take the lower capacity, and sunny rooms or rooms with more than two people regularly take the higher one.

AdjustmentOn the 6,000 rowOn the 7,000 rowSource
Heavily shaded, reduce capacity 10%6,000 − 10% = 5,400 BTU/hr7,000 − 10% = 6,300 BTU/hrENERGY STAR
Very sunny, increase capacity 10%6,000 + 10% = 6,600 BTU/hr7,000 + 10% = 7,700 BTU/hrENERGY STAR
Each additional person beyond two6,000 + 600 BTU/hr = 6,600 BTU/hr7,000 + 600 BTU/hr = 7,600 BTU/hrENERGY STAR
Unit used in a kitchen6,000 + 4,000 BTU/hr = 10,000 BTU/hr7,000 + 4,000 BTU/hr = 11,000 BTU/hrENERGY STAR

10% of 6,000 BTU/hr is 600 BTU/hr (6,000 × 10%).

10% of 7,000 BTU/hr is 700 BTU/hr (7,000 × 10%).

Shaded 250 sq ft: start at 6,000 and subtract 10% to reach 5,400 BTU/hr. Sunny 250 sq ft: start at 7,000 and add 10% to reach 7,700 BTU/hr. One person beyond two on the upper row is 7,000 + 600 = 7,600 BTU/hr. A kitchen at this floor area adds 4,000 to the row you already picked, which is 10,000 BTU/hr from the low row or 11,000 BTU/hr from the high row. Do not add the kitchen figure and also jump rows "to be safe" unless the room is both a kitchen and sunny.

Hold the ceiling check until the row is chosen. The capacities assume an 8-foot ceiling. A higher ceiling is ENERGY STAR's cue to select a room air conditioner with a higher CADR, not a license to invent a third row between 6,000 and 7,000.

Room-AC chart: both of these capacities are room air conditioner sizes. Central equipment for the house is a load calculation on the HVAC load calculator, not a midpoint of 6,000 and 7,000.

Where a window opening will not take the unit, compare a ductless head in the mini-split room size guide.

Affiliate

7,000 BTU window air conditioners on Amazon Window air conditioner insulation foam on Amazon

Related questions

All of these questions are listed on the topic map.

Sources

Frequently asked questions

Is a 250 sq ft room 6,000 or 7,000 BTU/hr?

150 up to 250 sq ft is 6,000 BTU/hr, and 250 up to 300 sq ft is 7,000 BTU/hr. Heavy shade keeps the room on 6,000. A very sunny exposure, or more than two people regularly, is the reason to start at 7,000.

Which matters more here, the row or the 10% adjustment?

The two rows differ by 1,000 BTU/hr (7,000 − 6,000). Ten percent of 6,000 is only 600 BTU/hr, and ten percent of 7,000 is 700 BTU/hr. The boundary choice is larger than the shade tweak, so pick the row before you apply 10%.

What does a kitchen adder do at 250 sq ft?

Add 4,000 BTU/hr after the row is chosen. From 6,000 that is 10,000 BTU/hr. From 7,000 that is 11,000 BTU/hr. People are separate: one person beyond two adds 600 BTU/hr on top of whichever row you picked.

Does a higher ceiling change the 250 sq ft row?

The chart is built on an 8-foot ceiling. ENERGY STAR does not give a new sq ft cutoff for a taller room. It says you may want a room air conditioner with a higher CADR. A central system is outside this chart; use the HVAC load calculator.